Influence of AC Filter Switching at Guangzhou Converter Station on Commutation Failure of Tianshengqiao-Guangzhou HVDC Project

Huifan XIE, Guangyuan YANG, Guangqiang PENG, Xiaopeng CHEN

South Power Sys Technol ›› 2015, Vol. 9 ›› Issue (9) : 17-22.

PDF(1867 KB)
Home Journals Southern Power System Technology
Southern Power System Technology

Abbreviation (ISO4): South Power Sys Technol      Editor in chief:

About  /  Aim & scope  /  Editorial board  /  Indexed  /  Contact  / 
PDF(1867 KB)
South Power Sys Technol ›› 2015, Vol. 9 ›› Issue (9) : 17-22. DOI: 10.13648/j.cnki.issn1674-0629.2015.09.003
HVDC Transmission

Influence of AC Filter Switching at Guangzhou Converter Station on Commutation Failure of Tianshengqiao-Guangzhou HVDC Project

Author information +
History +

Abstract

“10·04” commutation failure of 500 kV Tianshengqiao-Guangzhou HVDC is simulated and analyzed with RTDS tool, and the influence of AC filter switching operation on the transient process and commutation failure of Tianshengqiao-Guangzhou HVDC are systemically studied.The main conclusions are as follows: “10·04” commutation failure of Tianshengqiao-Guangzhou HVDC is caused by the 90° delayed closing of the AC filter after AC current crosses zero point, which leads to AC voltage distortion; the effective short-circuit-ratio of Guangzhou converter station is small, if AC filter input delay angle is too large, AC voltage will be distorted and result in commutation failure, but due to the short voltage distortion duration, this will not cause continuous commutation failure or DC block; in case of serious AC bus voltage distortion caused by improper AC filter switching operation, with the increase of DC power, the more DC voltage drops, the more significantly DC current increases, the more converter transformer side current reduces, the more easily commutation failure occurs in DC system; reducing the dispersing of AC Filter switching operation and ensuring an ideal angle can effectively prevent commutation failure caused by AC filter large angle closing.

Key words

Tianshengqiao-Guangzhou HVDC project / commutation failure / AC filter / dispersing of AC filter switching

Cite this article

Download Citations
Huifan XIE , Guangyuan YANG , Guangqiang PENG , et al. Influence of AC Filter Switching at Guangzhou Converter Station on Commutation Failure of Tianshengqiao-Guangzhou HVDC Project[J]. Southern Power System Technology. 2015, 9(9): 17-22 https://doi.org/10.13648/j.cnki.issn1674-0629.2015.09.003

References

[1]
洪潮. 直流输电系统换相失败和功率恢复特性的工程实例仿真分析[J]. 南方电网技术, 2011, 5(1):1-7.
HONG Chao. Simulation analysis on the commutation failure and power recovery characteristic of an actual DC transmission system[J]. Southern Power System Technology, 2011, 5(1):1-7.
[2]
邵震. 高压直流系统换相失败对交流侧继电保护的影响[J]. 南方电网技术, 2007, 1(1):77-80.
SHAO Zhen. Influence of HVDC commutation failure on AC relay protection[J]. Southern Power System Technology, 2007, 1(1):77-80.
[3]
王学之, 周全, 国建宝. 南方电网直流换相失败机理及判别方法[J]. 南方电网技术, 2013, 7(6):44-47.
WANG Xuezhi, ZHOU Quan, GUO Jianbao. The mechanism and discrimination method of HVDC commutation failure in China Southern Power Grid[J]. Southern Power System Technology, 2013, 7(6):44-47.
[4]
陈建斌, 周保荣, 熊卿, 等. 溪洛渡直流工程换相失败特性及相关因素分析[J]. 南方电网技术, 2013, 7(6):48-52.
CHEN Jianbin, ZHOU Baorong, XIONG Qing, et al. Analysis on the characteristics of commutation failure and its related factors of Xiluodu-Guangdong HVDC project[J]. Southern Power System Technology, 2013, 7(6):48-52.
[5]
赵利刚, 赵勇, 洪潮, 等. 基于实际录波的南方电网多回直流换相失败分析[J]. 南方电网技术, 2014, 8(4):42-46.
ZHAO Ligang, ZHAO Yong, HONG Chao, et al. Analysis on commutation failure of the CSG’s HVDC systems based on actual waves[J]. Southern Power System Technology, 2014, 8(4):42-46.
[6]
浙江大学发电教研组直流输电科研组. 直流输电[M]. 北京: 水利电力出版社, 1985.
[7]
刘炳君, 李世作. 高压交直流混合输电系统换相失败的研究[J]. 电气开关, 2010(1):27-30.
LIU Bingjun, LI Shizuo. Study on commutation failure of HV AC-DC hybrid power transmission system[J]. Electrical Switch, 2010(1):27-30.
[8]
高彩亮. 高压直流输电系统换相失败诊断研究[D]. 广州: 华南理工大学, 2010.
[9]
何朝荣, 李兴源, 金小明, 等. 高压直流输电系统换相失败的判断标准[J]. 电网技术, 2006, 30(22):19-23.
HE Chaorong, LI Xingyuan, JIN Xiaoming, et al. Criteria for commutation failure in HVDC transmission system[J]. Power System Technology, 2006, 30(22):19-23.
[10]
荆勇, 欧开健, 任震. 交流单相故障对高压直流输电换相失败的影响[J]. 高电压技术, 2004, 30(3):60-62.
JING Yong, OU Kaijian, REN Zhen. Analysis on influence of AC single phase faults on HVDC commutation failure[J]. High Voltage Engineering, 2004, 30(3):60-62.
[11]
欧开健, 任震, 荆勇. 直流输电系统换相失败的研究(一)换相失败的影响因素分析[J]. 电力自动化设备, 2003, 23(5):5-8.
OU Kaijian, REN Zhen, JING Yong. Research on commutation failure in HVDC transmission system part 1: commutation failure factors analysis[J]. Electric Power Automation Equipment, 2003, 23(5):5-8.
[12]
陈树勇, 李新年, 余军, 等. 基于正余弦分量检测的高压直流换相失败预防方法[J]. 中国电机工程学报, 2005, 25(14):1-6.
CHEN Shuyong, LI Xinnian, YU Jun, et al. A method based on the SIN-COS components detection mitigates commutation failure in HVDC[J]. Proceedings of the CSEE, 2005, 25(14):1-6.
PDF(1867 KB)

Accesses

Citation

Detail

Sections
Recommended

/

〈 〉