Power Loss Analysis and Energy Saving Measures of 500 kV Submarine Cables

Lei LIU, Bin LI, Bing LUO, Tianwei LI, Min LI

South Power Sys Technol ›› 2015, Vol. 9 ›› Issue (9) : 71-75.

PDF(828 KB)
Home Journals Southern Power System Technology
Southern Power System Technology

Abbreviation (ISO4): South Power Sys Technol      Editor in chief:

About  /  Aim & scope  /  Editorial board  /  Indexed  /  Contact  / 
PDF(828 KB)
South Power Sys Technol ›› 2015, Vol. 9 ›› Issue (9) : 71-75. DOI: 10.13648/j.cnki.issn1674-0629.2015.09.010
High Voltage & Insulation

Power Loss Analysis and Energy Saving Measures of 500 kV Submarine Cables

Author information +
History +

Abstract

Due to the special laying environment, the loss of submarine cables is one of the focuses in the design and model selection stage, especially the loss in the landing parts of the cables which generates heat and becomes a bottleneck to constrain the transfer current. Basod on analysis of structure and loss influence factors, the calculation model is set up. For Hainan interconnection project II, the loss and economic operation cost of four different armoring 500 kV cables at three laying environment (the bottom of the sea, tidal flats, landing parts) are calculated, and the flat copper wire armoured cable is proposed as the first choice for submarine project. Finally, the effective energy saving measures for the landing parts are analyzed.

Key words

500 kV submarine cables / loss / armoured type / energy saving

Cite this article

Download Citations
Lei LIU , Bin LI , Bing LUO , et al . Power Loss Analysis and Energy Saving Measures of 500 kV Submarine Cables[J]. Southern Power System Technology. 2015, 9(9): 71-75 https://doi.org/10.13648/j.cnki.issn1674-0629.2015.09.010

References

[1]
陈凌云, 朱熙樵, 李泰军. 海南联网工程海底电缆的选择[J]. 高电压技术, 2006, 32(7):39-42.
CHEN Lingyun, ZHU Xiqiao, LI Taijun. Choice of submarine cable of Hainan interconnection project[J]. High Voltage Engineering, 2006, 32(7):39-42.
[2]
王裕霜. 国内外海底电缆输电工程综述[J]. 南方电网技术, 2012, 6(2):26-30.
WANG Yushuang. Review on submarine cable projects for power transmission worldwide[J]. Southern Power System Technology, 2012, 6(2):26-30.
[3]
龙志, 袁力翔. 海南电网与南方主网第二回联网工程方案研究[J]. 南方电网技术, 2015, 9(4):80-83.
LONG Zhi, YUAN Lixiang. Scheme research for interconnection project II of Hainan Power Grid and China Southern Power Grid[J]. Southern Power System Technology, 2015, 9(4):80-83.
[4]
张磊, 郑新龙, 宣耀伟, 等. 110 kV单芯海缆铠装损耗试验研究[J]. 电线电缆, 2013(5):22-25.
ZHANG Lei, ZHENG Xinlong, XUAN Yaowei, et al. Experimental study on the armored loss of 110kV single-core submarine cable[J]. Electric Wire and Cable, 2013(5):22-25.
[5]
何旭涛, 马兴端, 闫循平. 降低高压海底电缆登陆段电能损耗的措施研究[J]. 浙江电力, 2011(10):29-31.
HE Xutao, MA Xingduan, YAN Xunping. Research on power loss reduction measure for landing parts of high voltage submarine power cables[J]. Zhejiang Electric Power, 2011(10):29-31.
[6]
JB/T 10181—2000,电缆载流量计算[S].
[7]
刘子玉, 王惠明. 电力电缆结构设计原理[M]. 西安: 西安交通大学出版社,1995:223-225.
[8]
牛海清, 王晓兵, 蚁泽沛, 等. 110 kV单芯电缆金属护套环流计算与试验研究[J]. 高电压技术, 2005, 31(8):15-17.
NIU Haiqing, WANG Xiaobing, YI Zepei, et al. Study on circulating current of 110 kV single-core cable[J]. High Voltage Engineering, 2005, 31(8):15-17.
[9]
邓长胜, 周汉亮. 磁性不锈钢丝编织铠装损耗的实验研究[J]. 电线电缆, 2005,(1):22-24.
DENG Changsheng, ZHOU Hanliang. Experimental study on the loss of the armour consisting of magnetic stainless steel braid[J]. Electric Wire and Cable, 2005, (1):22-24.
[10]
沃泽克. 海底电力电缆—设计、安装、修复和环境影响[M]. 北京: 机械工业出版社, 2011.
[11]
高震, 章正国, 郑新龙, 等. 非磁性铝合金铠装海缆损耗实验研究[J]. 电网与清洁能源, 2013, 29(5):4-8.
GAO Zhen, ZHANG Zhengguo, ZHENG Xinlong, et al. Experimental study on the non-magnetic aluminum armored submarine cable loss[J]. Power System and Clean Energy, 2013, 29(5):4-8.
[12]
王星, 尚涛, 黄贤球, 等. 海南联网海底电缆护套绝缘监测方法[J]. 南方电网技术, 2009, 3(1):62-65.
WANG Xing, SHANG Tao, HUAN Xianqiu, et al. The insulation inspection method for submarine cable sheath of Hainan grid interconnection project[J]. Southern Power System Technology, 2009, 3(1):62-65.
[13]
王裕霜. 500 kV海底电缆浅滩铸铁套管保护实践与思考[J]. 南方电网技术, 2011, 5(2):1-3.
WANG Yushuang. The practice of cast iron shell protection of 500 kV submarine cable in immediate off-shore areas and the relative concerns[J]. Southern Power System Technology, 2011, 5(2):1-3.
[14]
龚永超, 何旭涛, 孙建生, 等. 高压海底电力电缆铠装的设计和选型[J]. 电线电缆, 2011(5):19-22.
GONG Yongchao, HE Xutao, SUN Jiansheng, et al. The design and selection of high-voltage submarine power cable armor[J]. Electric Wire and Cable, 2011 (5):19-22.
[15]
吴海飞, 夏华丽, 黄金花. 海底电缆工程计价依据研究[J]. 电网技术, 2011, 35(增刊2):128-133.
WU Haifei, XIA Huali, HUANG Jinhua. Research on pricing basis of seabed cable engineering[J]. Power System Technology, 2011, 35(S2):128-133.
[16]
孟毓, 王建辉. 采用水冷却提高隧道内电缆的输送容量[J]. 电力建设, 2010, 31(11):54-56.
MENG Yu, WANG Jianhui. Inceasing transmission capacity of cables by water cooling system[J]. Electric Power Construction, 2010, 31(11):54-56.
[17]
KUMAI W, HASHIMOTO I. Completion of high-efficiency water pipe cooling system for underground transmission line[J]. IEEE Transactions on Power Delivery, 1994, 9(1):585-590.