Application of Multi-Model Adaptive Statistical Iterative Reconstruction-Veo in Ultra-Low Dose Chest CT Examination of Children in Plateau Area

WANGXiantao, BAIRuiting, Cidanwangjiu, Suolangnima, Nimazhuoga, SUBaiyan

Acta Academiae Medicinae Sinicae ›› 2025, Vol. 47 ›› Issue (1) : 29-34.

PDF(4789 KB)
Home Journals Acta Academiae Medicinae Sinicae
Acta Academiae Medicinae Sinicae

Abbreviation (ISO4): Acta Academiae Medicinae Sinicae      Editor in chief: Xuetao CAO

About  /  Aim & scope  /  Editorial board  /  Indexed  /  Contact  / 
PDF(4789 KB)
Acta Academiae Medicinae Sinicae ›› 2025, Vol. 47 ›› Issue (1) : 29-34. DOI: 10.3881/j.issn.1000-503X.16068
Original Article

Application of Multi-Model Adaptive Statistical Iterative Reconstruction-Veo in Ultra-Low Dose Chest CT Examination of Children in Plateau Area

Author information +
History +

Abstract

Objective To explore the application value of multi-model adaptive statistical iterative reconstruction-Veo (ASiR-V) in ultra-low dose chest CT examination of children in the plateau area. Methods The children who underwent chest CT examination in Xizang Autonomous Region People’s Hospital were enrolled in this study and assigned into two groups according to the scanning conditions.Group A underwent scanning at a tube voltage of 100 kV and ASiR-V 50% reconstruction,and group B underwent scanning at a tube voltage of 80 kV and ASiR-V 0 (Group B1) and ASiR-V 50% (Group B2) reconstruction.The image quality of each group was evaluated objectively and subjectively.The radiation dose and image quality were compared between groups. Results Groups A and B showed the volume CT dose indexes of (2.33±0.62) mGy and (0.86±0.01) mGy and the dose length products of (65.01±25.12) mGy·cm and (23.55±3.38) mGy·cm,respectively,which presented differences between groups (both P<0.001).The image noise in the bilateral upper and middle lung areas in group B2 was lower than that in group B1 but higher than that in group A (all P<0.001).There was no significant difference in image quality score of the lung window among groups (all P>0.05).Groups A,B1,and B2 had no significant differences in ascending aorta (P=0.538) or liver CT value (P=0.175) in the mediastinal window.The signal-to-noise ratios and contrast-to-noise ratios of ascending aorta and liver in group B2 were higher than those in group B1 (all P<0.001) and lower than those in group A (all P<0.05).The image quality score of the mediastinal window followed a descending order of group A>group B2>group B1 (all P<0.001)。Conclusion ASiR-V combined with low tube voltage can effectively reduce the radiation dose and guarantee the image quality of chest CT of children in the plateau area.

Key words

adaptive statistical iterative reconstruction-Veo / children / low dose / multislice spiral CT

Cite this article

Download Citations
WANG Xiantao , BAI Ruiting , Cidanwangjiu , et al . Application of Multi-Model Adaptive Statistical Iterative Reconstruction-Veo in Ultra-Low Dose Chest CT Examination of Children in Plateau Area[J]. Acta Academiae Medicinae Sinicae. 2025, 47(1): 29-34 https://doi.org/10.3881/j.issn.1000-503X.16068

References

[1]
Wang WH, Sung CY, Wang SC, et al. Risks of leukemia,intracranial tumours and lymphomas in childhood and early adulthood after pediatric radiation exposure from computed tomography[J]. CMAJ, 2023, 195(16):E575-E583.DOI:10.1503/cmaj.221303.
[2]
Bosch de Basea Gomez M, Thierry-Chef I, Harbron R, et al. Risk of hematological malignancies from CT radiation exposure in children,adolescents and young adults[J]. Nat Med, 2023, 29(12):3111-3119.DOI:10.1038/s41591-023-02620-0.
[3]
Foucault A, Ancelet S, Dreuil S, et al. Childhood cancer risks estimates following CT scans:an update of the French CT cohort study[J]. Eur Radiol, 2022, 32(8):5491-5498.DOI:10.1007/s00330-022-08602-z.
Increased risks of central nervous system (CNS) tumors and leukemia associated with computed tomography (CT) exposure during childhood have been reported in recent epidemiological studies. However, no evidence of increased risks was suggested in a previous analysis of the French CT cohort. This study benefits from an updated cohort with a longer follow-up and a larger sample size of patients.The patients were followed from the date of their first CT (between 2000 and 2011) until their date of cohort exit defined as the earliest among the following: 31 December 2016, date of death, date of first cancer diagnosis or date of their 18 birthday. Cancer incidence, vital status, cancer predisposing factors (PFs), and additional CT scans were collected via external national databases. Hazard ratios (HRs) associated to cumulative organ doses and sex were estimated from Cox models.At the end of follow-up, mean cumulative doses were 27.7 and 10.3 mGy for the brain and the red bone marrow (RBM), respectively. In patients without PFs, an HR per 10 mGy of 1.05 (95% CI: 1.01-1.09) for CNS tumors, 1.17 (95% CI: 1.09-1.26) for leukemia, and 0.96 (95% CI: 0.63-1.45) for lymphoma was estimated. These estimates were not modified by the inclusion of CT scans performed outside the participating hospitals or after the inclusion period.This study shows statistically significant dose-response relationships for CNS tumors and leukemia for patients without PFs.• Computed tomography is the most important contributor to the collective dose for diagnostic imaging to the French population. • Concerns have been raised about possible cancer risks, particularly after exposure to CT in childhood, due to the greater radiation sensitivity of children and to their longer life expectancy. • Analysis of the updated French CT cohort shows statistically significant dose-response relationships for CNS tumors and leukemia.© 2022. The Author(s), under exclusive licence to European Society of Radiology.
[4]
牛亚婷, 苏垠平, 牛延涛, 等. 儿童CT扫描致癌风险评估研究进展[J]. 中华放射医学与防护杂志, 2020, 40(2):156-160.DOI:10.3760/cma.j.issn.0254-5098.2020.02.015.
[5]
Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours:a retrospective cohort study[J]. Lancet, 2012, 380(9840):499-505.DOI:10.1016/S0140-6736(12)60815-0.
Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults.In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT.During follow-up, 74 of 178,604 patients were diagnosed with leukaemia and 135 of 176,587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005-0·120; p=0·0097) and brain tumours (0·023, 0·010-0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46-6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50-74 mGy (mean dose 60·42 mGy) was 2·82 (1·33-6·03).Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10,000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate.US National Cancer Institute and UK Department of Health.Copyright © 2012 Elsevier Ltd. All rights reserved.
[6]
中华医学会儿科学分会影像学组, 中华医学会放射学分会儿科学组. 儿童CT检查辐射剂量标准中国专家共识[J]. 中华放射学杂志, 2024, 58(2):158-164.DOI:10.3760/cma.j.cn112149-20231013-00291.
[7]
孙记航, 段晓岷, 于彤, 等. 儿童CT扫描辐射剂量现状调查和诊断参考水平的初步探讨[J]. 中华放射学杂志, 2022, 56(10):1135-1140.DOI:10.3760/cma.j.cn112149-20220214-00115.
[8]
Kanal KM, Butler PF, Chatfield MB, et al. US diagnostic reference levels and achievable doses for 10 pediatric CT examinations[J]. Radiology, 2022, 302(1):164-174.DOI:10.1148/radiol.2021211241.
[9]
李润根, 时超刚, 赵静, 等. 欧洲儿童CT成像的诊断参考水平[J]. 中华放射医学与防护杂志, 2020, 40(4):326-332.DOI:10.3760/cma.j.issn.0254-5098.2020.04.014.
[10]
孙记航, 王帆宁, 段晓岷, 等. 自适应迭代重建技术结合高分辨算法提高儿童低剂量胸部CT肺脏病变显示的能力[J]. 中国医学影像技术, 2017, 33(5):773-777.DOI:10.13929/j.1003-3289.201610011.
[11]
魏伟安, 杨吉钱, 熊胜, 等. 噪声指数结合多模型自适应迭代重建在学龄前儿童上腹部CT扫描中的应用价值[J]. 放射学实践, 2021, 36(9):1137-1141.DOI:10.13609/j.cnki.1000-0313.2021.09.012.
[12]
柴亚如, 邢静静, 高剑波, 等. 多模型迭代重建算法对腹部体模CT扫描图像质量和辐射剂量的影响[J]. 中国医学影像技术, 2018, 34(1):118-122.DOI:10.13929/j.1003-3289.201704047.
[13]
蒋东, 秦立新, 田葵, 等. 能谱纯化结合高级迭代重建在儿童胸部超低剂量CT的应用初探[J]. 实用放射学杂志, 2021, 37(9):1536-1538,1549.DOI:10.3969/j.issn.1002-1671.2021.09.033.
[14]
赵凡惠, 王雷, 李建龙, 等. 儿童胸部低剂量CT扫描中最佳KARL迭代重建等级的研究[J]. 中国CT和MRI杂志, 2020, 18(11):55-58.DOI:10.3969/j.issn.1672-5131.2020.11.018.
[15]
Viry A, Aberle C, Lima T, et al. Assessment of task-based image quality for abdominal CT protocols linked with national diagnostic reference levels[J]. Eur Radiol, 2022, 32(2):1227-1237.DOI:10.1007/s00330-021-08185-1.
[16]
边传振, 卞宠平, 戴石, 等. 外伤儿童胸腹部联合CT扫描的低剂量研究[J]. 临床放射学杂志, 2019, 38(9):1742-1746.DOI:10.13437/j.cnki.jcr.2019.09.038.
[17]
李锋坦, 李东, 张云亭. 管电压对CT值测量、辐射剂量及图像质量影响的模型研究[J]. 中华放射学杂志, 2013, 47(5):458-461.DOI:10.3760/cma.j.issn.1005-1201.2013.05.016.
[18]
谭辉, 韩冬, 张敏, 等. ASiR-V在提高低管电压颅脑CT图像中的临床应用[J]. 中国CT和MRI杂志, 2022, 20(9):4-5,8.DOI:10.3969/j.issn.1672-5131.2022.09.002.
[19]
孙记航, 阴捷, 刘志敏, 等. 基于模型的迭代重建算法应用于80 kV低剂量儿童胸部CT的可行性[J]. 中国医学影像技术, 2017, 33(4):599-602.DOI:10.13929/j.1003-3289.201608014.
[20]
尤志军, 石明国, 李剑, 等. 在CT成像中优化扫描参数对减少辐射剂量的作用[J]. 医疗卫生装备, 2010, 31(4):380-381.DOI:CNKI:SUN:YNWS.0.2010-04-233.
[21]
丁婕, 何维恒, 杨利莉, 等. ASiR-V联合70 kV个性化轴扫在小儿肺炎CT扫描中的可行性探究[J]. 中国临床医学影像杂志, 2018, 29(7):475-478.DOI:10.12117/jccmi.2018.07.006.
[22]
鄢迪, 陈斌, 章群, 等. 基于成年人体重及体重指数估算胸腹部CT体型特异性辐射剂量[J]. 中国医学影像学杂志, 2022, 30(11):1171-1177.DOI:10.3969/j.issn.1005-5185.2022.11.018.
[23]
杨林, 赵磊, 刘京华. 低剂量扫描技术对图像质量及CT值的影响[J]. 医学影像学杂志, 2023, 33(5):866-870.
[24]
Shirasaka T, Kojima T, Funama Y, et al. Image quality improvement with deep learningbased reconstruction on abdominal ultrahighresolution CT:a phantom study[J]. J Appl Clin Med Phys, 2021, 22(7):286296.DOI:10.1002/acm2.13318.
[25]
王同明. 前置与后置多模型迭代重组算法在腹部体模CT扫描中的对比研究[J]. 临床放射学杂志, 2018, 37(5):878-881.
PDF(4789 KB)

Accesses

Citation

Detail

Sections
Recommended

/